Skip to content

Make critical point calculation more robust #236

Open

Description

@g-bauer

Depending on initial values, the critical point routine may return the wrong state. We currently only check if the result for a temperature is OK (and then we don't check additional temperatures) but a more rigorous check is needed.

Activity

  1. added
    enhancementNew feature or request
    corerelated to features in feos-core
    on Apr 11, 2024
  2. ianhbell commented on May 24, 2024

    @ianhbell

    Are you concerned with pure fluids or mixtures here?

  3. g-bauer commented on May 28, 2024

    @g-bauer
    ContributorAuthor

    @ianhbell Pure fluids for now. I noticed in the SAFT-VR Mie notebook when I tried to reproduce Lafitte's results that some seemingly converged results are not correct. Changing the initial temperature solves this and so does a stability analysis - but is expensive to run.

  4. ianhbell commented on May 28, 2024

    @ianhbell

    Also, as I gather, they used something like centered finite derivatives in their thermodynamic modeling for higher derivatives, so you should not expect agreement to be as good as with FeOs, teqp, or Clapeyron.jl. I couldn't reproduce their critical points in their paper to all their given digits.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    corerelated to features in feos-coreenhancementNew feature or request

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions