from __future__ import print_function
def connect(route, **args):
return MLX90614(route, **args)
class MLX90614():
NUMPLOTS = 1
PLOTNAMES = ['Temp']
ADDRESS = 0x5A
name = 'PIR temperature'
def __init__(self, I2C, **args):
self.I2C = I2C
self.ADDRESS = args.get('address', self.ADDRESS)
self.OBJADDR = 0x07
self.AMBADDR = 0x06
self.source = self.OBJADDR
self.name = 'Passive IR temperature sensor'
self.params = {'readReg': {'dataType': 'integer', 'min': 0, 'max': 0x20, 'prefix': 'Addr: '},
'select_source': ['object temperature', 'ambient temperature']}
try:
print('switching baud to 100k')
self.I2C.configI2C(100e3)
except Exception as e:
print('FAILED TO CHANGE BAUD RATE', e.message)
def select_source(self, source):
if source == 'object temperature':
self.source = self.OBJADDR
elif source == 'ambient temperature':
self.source = self.AMBADDR
def readReg(self, addr):
x = self.getVals(addr, 2)
print(hex(addr), hex(x[0] | (x[1] << 8)))
def getVals(self, addr, numbytes):
vals = self.I2C.readBulk(self.ADDRESS, addr, numbytes)
return vals
def getRaw(self):
vals = self.getVals(self.source, 3)
if vals:
if len(vals) == 3:
return [((((vals[1] & 0x007f) << 8) + vals[0]) * 0.02) - 0.01 - 273.15]
else:
return False
else:
return False
def getObjectTemperature(self):
self.source = self.OBJADDR
val = self.getRaw()
if val:
return val[0]
else:
return False
def getAmbientTemperature(self):
self.source = self.AMBADDR
val = self.getRaw()
if val:
return val[0]
else:
return False