Skip to content

Conversation

@JohnAZoidberg
Copy link
Member

After the system turns off and no AC power is present, the EC waits a few seconds and then turns off completely.
Using this command we can find out what that delay is and change it.

> framework_tool.exe --ec-hib-delay 30
EC Hibernation Delay: 30s

After the system turns off and no AC power is present, the EC waits a
few seconds and then  turns off completely.
Using this command we can find out what that delay is and change it.

```
> framework_tool.exe --ec-hib-delay 30
EC Hibernation Delay: 30s
```

Signed-off-by: Daniel Schaefer <dhs@frame.work>
@JohnAZoidberg
Copy link
Member Author

Tested on Framework 13 AMD Ryzen AI 300. Set delay to 120s and EC turns off after 2 minutes.
I opened the chassis and checkec when the blinking light stops.

@JohnAZoidberg JohnAZoidberg merged commit 5ba932e into main May 2, 2025
6 checks passed
@JohnAZoidberg JohnAZoidberg deleted the hibernate-delay branch May 2, 2025 03:24