Skip to content

Latest commit

 

History

History
 
 

Folders and files

NameName
Last commit message
Last commit date

parent directory

..
 
 
 
 
 
 
 
 

README.md

to run digitisation with ccdb object enabling ccdb to anchor to data -> --use-ccdb-tof and --timestamp-tof 1635567000

second argument will be marked as obsolete once the framework will provide the timestamp

o2-sim-digitizer-workflow -b --onlyDet TOF --use-ccdb-tof --timestamp-tof 1635567000 --shm-segment-size 5000000000

you can attach also digit QC to check the output

|o2-qc -b --config json://$QUALITYCONTROL_ROOT/etc/tofdigits.json

for a more detailed output you can replace the data-policy of TaskDigits from tof-digits to tof-digits-dia and then enabling Diagnostic in TaskParameters

ccdb objects loaded

diagostic frequency (TRM errors, Readout errors, noisy)

channel offset+time sleewing (decalibration)

TOFFEElight map -> active channels